Multi-parameter analysers
Model: C3050 •C3051
Manufacture: CONSORT – Belgium
Origin: Belgium
Reference at: http://www.consort.be/
1.
Overview:
rH2:
-
Bio-electronic
multimeter for the study of the biological water quality or illnesses in body
fluids according to Vincent's method.
pH:
-
Multi-point (1...5)
calibration for more linearity.
-
Selectable
resolution from 0.001 pH to 0.1 pH.
-
Automatic
calibration with any of eleven pre-programmed and five user specified pH
buffers.
-
Accepts pH
electrodes with any zero point (Eo) between ±999 mV.
mV:
-
Features mV
calibration for accurate ORP measurements.
-
Selectable
resolution from 0.1 mV to 1 mV.
-
Can also show mV
referred to the standard hydrogen electrode.
Conductivity:
-
Multi-point (1...3)
calibration for more linearity.
-
An electrode with a
typical cell constant of 1 cm-1
(standard)
permits to measure from 0.01 µS/cm to 200 mS/cm in five ranges.
-
An electrode with a
typical cell constant of 0.1 cm-1 permits to measure from 0.001
µS/cm to 20 mS/cm in five ranges.
-
An electrode with a
typical cell constant of 10 cm-1 permits to measure from 0.1 µS/cm
to 2000 mS/cm in five ranges.
-
Automatically
selects correct range and frequency.
-
Selectable
reference temperature: 20° or 25°C.
-
Automatic
calibration with any of three preprogrammed and three user specified standard
solutions.
-
Accurate low
conductivity measurements by eliminating the capacitive component of the
electrode and its cable (avoid the use of long cables!).
µW:
-
Calculates the
resistance (Ω) and the quantification of Vincent (µW).
Temperature:
-
Manual or automatic
temperature compensation.
-
Calibrates
temperature probe for quality measurements.
Inputs:
-
Two inputs for pH,
mV or conductivity + corresponding temperature and reference inputs.
-
One extra input for
pH or mV + corresponding temperature and reference input.
Outputs: Two versions available:
-
C3050: with USB
communication port and RS232 interface.
-
C3051: with
Ethernet communication port and RS232 interface.
Data-logging:
-
Up to 12000 data
sets can be stored manually or at a programmable interval.
-
Allows to mix data
from all ranges in the same table.
Cabinet:
-
Robust dust and
splash-proof cabinet.
-
An optional wall
mounting kit allows to fix the meter to any wall making more space available on
the desk.
Display:
-
A large bright LCD
screen with white backlight enables to view all channels individually or
simultaneously.
-
Stability indicator
prompts the user when readings should be taken.
-
Hold function
allows to freeze the display for convenient reading or recording.
-
The interactive LCD
screen provides step by step instructions in the language of your choice
(English, Dutch, French, German).
-
Real-time clock
displays time and date.
-
Shows a GLP report
on the LCD screen.
Special features:
-
Two-way
communication with a computer using USB or RS232.
-
Can be programmed
to continue automatically with the measure-ments or data-logging after a power
failure.
-
Password protection
prevents any unauthorised modification of the instrument's settings.
-
No electrical
interference between pH/ORP and conductivity elec-trodes in the same solution.
-
Optional 12 V car
adaptor.
-
Three year
warranty.
GLP:
-
All procedures for
a "Good Laboratory Practice" are on board.
Pre-programmed standards:
-
pH buffers: 1.68,
2.00, 4.00, 4.01, 6.87, 7.00, 9.18, 9.21, 10.01, 12.00, 12.45 (at 25°C).
-
Conductivity: 1413
µS/cm, 12.88 mS/cm, 111.8 mS/cm (at 25°C).
2.
Technical Data:
pH:
-
Range: -2...+16 pH
-
Resolution: 0.001
pH
-
Accuracy: 0.1% ± 1
digit
-
Calibration: 1...5
points
-
Buffers: 11
pre-programmed; 5 user specified
-
Temperature
compensation: -5...+105°C
-
ISO-pH: 6...8 pH
-
Slope: 80...120%
-
Zero point (Eo):
±999 mV
mV:
-
Range: ±2000 mV
-
Resolution: 0.1 mV
-
Accuracy: 0.1% ± 1
digit
-
Calibration: 1
point
rH2:
-
Range: 0...42 rH2
-
Resolution: 0.01 rH2
-
Accuracy: 0.1% ± 1 digit
CONDUCTIVITY:
-
Range (cc dependent): 0...2000 mS/cm
-
Resolution (cc
dependent): 0.001 µS/cm
-
Accuracy: 0.5% f.s.
of range
-
Calibration: 1...3
points
-
Standards: 3
pre-programmed; 3 user specified
-
Cell constant (cc):
0.07...13 cm-1
-
Temperature
compensation: -5...+105°C
-
Reference
temperature: 20° or 25°C
-
Temperature
coefficient: natural waters (EN27888)
-
Range lock
-
Capacitive
compensation
RESISTIVITY:
-
Range: 0...200
MΩ.cm
-
Resolution: 1 Ω.cm
SALINITY:
-
Range: 0...70
-
Reference
temperature: 15°C
TDS:
-
Range: 0...100 g/l
-
Resolution: 0.01
mg/l
µW:
-
Range: 0...400000 µW
TEMPERATURE:
-
Range: -5...+105°C
-
Resolution: 0.1°C
-
Accuracy: 0.1°C
-
Calibration: 1
point
CHANNELS:
-
Measurement: 3 (conductivity: 2)
-
Temperature: 3
INPUTS:
-
Measurement: 3 BNC,
1012Ω
-
Temperature: 3x2
banana, for Pt1000
CALIBRATION:
-
Reminder: 0...999 h
-
GLP
DISPLAY:
-
LCD: 240x64 pixels
-
White backlight
-
Hold function
-
Selectable
resolution
-
Real time clock
COMMUNICATION:
-
Interface: with computer USB
-
RS232, baud rate:
1200...115200 b/s
-
Printer
DATA-LOGGING:
-
Data sets: 12000 + °C/date/time
-
Modes all
-
Manual or timed
-
Interval: 1...9999
s
SECURITY:
-
Identification number
-
Password protection
AMBIENT CONDITIONS:
-
Temperature: 0...40°C
-
Humidity: 0...95%,
non condensing
POWER SUPPLY:
-
Mains: 100...240 VAC, 50/60 Hz
-
Low voltage: 9...15
VDC
DIMENSIONS (WxDxH): 26x18x9 cm
WEIGHT: Meter 1 kg
Electrodes supplied with kit versions:
-
SP35B:
- pH+ ORP
- Glass body, 1 m cable
- 0...14 pH, 0...±2000 mV
- Single junction, refillable
-
SK20T:
§ Conductivity + ATC
§ Glass body, 1 m cable
§ 1 cm-1, 0...110°C
§ Dual graphite plates
3.
Order Info:
|
Item
|
Code
|
Description
|
|
01
|
C3050
|
Bio-electronic meter (USB version) + USB cable
|
|
02
|
C3051
|
Bio-electronic meter (Ethernet version) + UTP cable
|
|
03
|
C3050T
|
Meter kit complete: meter + pH/ORP electrode SP35B +
conductivity electrode SK20T+ 2x50 ml buffers (pH 4 and 7) + 50 ml
conductivity standard (0.01 M KCl) + 50 ml electrolyte (3M KCl) + 50 ml redox
standard (358 mV) + flexible electrode holder SH300
|
|
04
|
A4800
|
Wall mounting kit (optional)
|
|
05
|
A4049
|
Car adaptor, 12 V (optional)
|